PROFESSIONAL      INNOVATION      EXCELLENCE      SERVICE

Sales & Support
Request A Quote - Email
Select Language
English
Russian
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsPharmaceutical Water Treatment

High temperature purified water system +EDI system ,double High temperature RO Membrane

I'm Online Chat Now
Certification
China Shanghai ChongYang Water Treatment Equipment CO.,LTD. certification
China Shanghai ChongYang Water Treatment Equipment CO.,LTD. certification
The products made by CY-Water is excellent . We can get response quickly from them at any time .

—— Mr.Maher

High temperature purified water system +EDI system ,double High temperature RO Membrane

High temperature purified water system +EDI system ,double High temperature RO Membrane
High temperature purified water system +EDI system ,double High temperature RO Membrane High temperature purified water system +EDI system ,double High temperature RO Membrane High temperature purified water system +EDI system ,double High temperature RO Membrane High temperature purified water system +EDI system ,double High temperature RO Membrane High temperature purified water system +EDI system ,double High temperature RO Membrane

Large Image :  High temperature purified water system +EDI system ,double High temperature RO Membrane Get Best Price

Product Details:

Place of Origin: Made in China
Brand Name: CY-Water
Certification: ISO ,CE
Model Number: CY-PW-2000Liter/Hour

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Export Standard and Wood Package .
Delivery Time: 35 days after receiving the deposit .
Supply Ability: 10 Sets/Month
Detailed Product Description
Conductivity: 2--0.5 μs/cm Recovery Rate: >97%
RO Housing: SS 304 316 8040 4040 Connection: Clamp ,Welding
Power Supply: AC 220V / AC 380V / 415V±5% 50 HZ / 60HZ Valve Control: Pneumatic , Manual
Membrane: High Temperature Type

Product Name:High temperature purified water system +EDI system ,double High temperature RO Membrane

Risk Control :

Quartz sand ,activated carbon ---regularl pasteurize (record ,verification )

1st RO Membrane ----regularly clean,and pasteurize ( record ,verification)

2st RO Membrane ----regularly clean,and pasteurize ( record ,verification)

The 2nd RO water ---Testing on-line (Conductivity,PH ), There are critical alarm ,unqualified alarm (The pipeline can switch ,the unqualified water can be returned to the raw water tank ).

Storage Tank -----------regularly clean,and pasteurize ( record ,verification)

Distribution System ------Sanitary class booster pump ,conductivity &PH testing ,critical alarm and uanqualified alarm ( The pipeline can switch ,the unqualified water can be returned to the raw water tank)

Returning water part ----Double tube heating exchange ( record ,verification),flow velocity ,temperature test , conductivity ,unqualified PH Alarm(The pipeline can switch ,the unqualified water can be returned to the raw water tank)

The system own function of automatic control,the system smoothly runs under the situation of automatic protections , the system function is as following 

The system can automatically stop when the lack of water or fail to run. The system can automatically start when the pressure of tap water is normal ,meanwhile eliminate signal of alarm .

The booster pump and high pressure pump can automatically stop when the inlet pressure is lower than set value as equipment failure or mistaken by person , that cause damage of pump for ilding under no water , meanwhile avoid damage of filter,for that the booster pump continuously run can cause over high pressure  .

The booster pump can automatically stop when it couldn't sense the pressure that equipment failure or mistaken by person  cause ,that can effectively protect the whole equipment .   

The system can automatically stop when the storage tank is full ,  when the liquid level is lower than the middle liquid level ,the system can automatically start booster pump ,high pressure pump to make water till water storage water is full .

When the liquid level is lower than the low level ,the system can automatically stop supplying water , that can avoid damage of pump due to idling,when the liquid level is up to the middle level ,the pure water pump can start to recover water supply .

The core of equipment ----For there are multiple protection and program of flushing automatically for RO Device,the whole system fully automatically run ,maintain . that can assure the top water quality .

The RO membrane can be physical flushed  by the high pressure water that produce through high pressure pump. That can clean contaminant  on surface of RO ,expand to lifetime of RO Membrane.

All advance instrument  monitor water qualtiy on time ,the user can know condition of whole water treatment equipment at any time.

Power failure: The PLC can record automatically data,never lose . the electric control is equipped with UPS power supply .

 
Technical Parameter:

Output Water Capacity 0.5m3/h--50m3/h
TOC <100PPB
Conductivity <0.5μs/cm
Microorganism <100 CFU/ml
Endotoxin <0.25EU/ml
Nitrate <0.06PPM
Heavy metal <0.1 PPM

 
 

High temperature purified water system +EDI system ,double High temperature RO Membrane 0
 
 
 
Company :Shanghai
ChongYang Water Treatment Equipment CO.,LTD
Email:Sales@cy-waterequipment.com
Phone:+86 15900488030
Http://www.cy-waterequipment.com
 
 

Contact Details
Shanghai ChongYang Water Treatment Equipment CO.,LTD.

Contact Person: Ms. Yanni.Wang

Tel: 86 15900488030

Fax: 86-21-66126659

Send your inquiry directly to us