Product Details:
Payment & Shipping Terms:
|
Conductivity: | 2--0.5 μs/cm | Recovery Rate: | >97% |
---|---|---|---|
RO Housing: | SS 304 316 8040 4040 | Connection: | Clamp ,Welding |
Power Supply: | AC 220V / AC 380V / 415V±5% 50 HZ / 60HZ | Valve Control: | Pneumatic , Manual |
Membrane: | High Temperature Type |
Product Name:High temperature purified water system +EDI system ,double High temperature RO Membrane
Risk Control :
Quartz sand ,activated carbon ---regularl pasteurize (record ,verification )
1st RO Membrane ----regularly clean,and pasteurize ( record ,verification)
2st RO Membrane ----regularly clean,and pasteurize ( record ,verification)
The 2nd RO water ---Testing on-line (Conductivity,PH ), There are critical alarm ,unqualified alarm (The pipeline can switch ,the unqualified water can be returned to the raw water tank ).
Storage Tank -----------regularly clean,and pasteurize ( record ,verification)
Distribution System ------Sanitary class booster pump ,conductivity &PH testing ,critical alarm and uanqualified alarm ( The pipeline can switch ,the unqualified water can be returned to the raw water tank)
Returning water part ----Double tube heating exchange ( record ,verification),flow velocity ,temperature test , conductivity ,unqualified PH Alarm(The pipeline can switch ,the unqualified water can be returned to the raw water tank)
The system own function of automatic control,the system smoothly runs under the situation of automatic protections , the system function is as following
The system can automatically stop when the lack of water or fail to run. The system can automatically start when the pressure of tap water is normal ,meanwhile eliminate signal of alarm .
The booster pump and high pressure pump can automatically stop when the inlet pressure is lower than set value as equipment failure or mistaken by person , that cause damage of pump for ilding under no water , meanwhile avoid damage of filter,for that the booster pump continuously run can cause over high pressure .
The booster pump can automatically stop when it couldn't sense the pressure that equipment failure or mistaken by person cause ,that can effectively protect the whole equipment .
The system can automatically stop when the storage tank is full , when the liquid level is lower than the middle liquid level ,the system can automatically start booster pump ,high pressure pump to make water till water storage water is full .
When the liquid level is lower than the low level ,the system can automatically stop supplying water , that can avoid damage of pump due to idling,when the liquid level is up to the middle level ,the pure water pump can start to recover water supply .
The core of equipment ----For there are multiple protection and program of flushing automatically for RO Device,the whole system fully automatically run ,maintain . that can assure the top water quality .
The RO membrane can be physical flushed by the high pressure water that produce through high pressure pump. That can clean contaminant on surface of RO ,expand to lifetime of RO Membrane.
All advance instrument monitor water qualtiy on time ,the user can know condition of whole water treatment equipment at any time.
Power failure: The PLC can record automatically data,never lose . the electric control is equipped with UPS power supply .
Technical Parameter:
Output Water Capacity | 0.5m3/h--50m3/h |
TOC | <100PPB |
Conductivity | <0.5μs/cm |
Microorganism | <100 CFU/ml |
Endotoxin | <0.25EU/ml |
Nitrate | <0.06PPM |
Heavy metal | <0.1 PPM |
Company :Shanghai ChongYang Water Treatment Equipment CO.,LTD
Email:Sales@cy-waterequipment.com
Phone:+86 15900488030
Http://www.cy-waterequipment.com
Contact Person: Ms. Yanni.Wang
Tel: 86 15900488030