PROFESSIONAL      INNOVATION      EXCELLENCE      SERVICE

Sales & Support
Request A Quote - Email
Select Language
English
Russian
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsBoiler Feed Water Treatment Systems

Energy Saving Boiler Feed Water Treatment Solution with PLC Control

Energy Saving Boiler Feed Water Treatment Solution with PLC Control

Energy Saving Boiler Feed Water Treatment Solution with PLC Control
Energy Saving Boiler Feed Water Treatment Solution with PLC Control Energy Saving Boiler Feed Water Treatment Solution with PLC Control Energy Saving Boiler Feed Water Treatment Solution with PLC Control Energy Saving Boiler Feed Water Treatment Solution with PLC Control

Large Image :  Energy Saving Boiler Feed Water Treatment Solution with PLC Control Get Best Price

Product Details:

Place of Origin: CHINA
Brand Name: CHONGYANG
Certification: ISO,CE
Model Number: CY-RO-1000T-100000T

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Export Standard Wooden Box
Delivery Time: With 30-40 Days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/Month
Detailed Product Description
Application: Boiler Feed Water Treatment Capacity: 1TPH-100TPH
Technology: RO / EDI / Softener Control System: PLC Automatic Control,Semi-Automatic Control, Manual Control
Material: SS304 / SS316 / FRP Voltage: 220V / 380V / 415V
Water Source: Tap Water / Underground Water Function: Boiler Feed Water Purification
Membrane Brand: Vontron / Dow / Hydranautics Pipe Material: UPVC / Stainless Steel
Conductivity: Customized Installation Type: Skid Mounted
Certification: CE / ISO9001

Energy Saving Boiler Feed Water Treatment Solution with PLC Control

1. Product Introduction

The Energy Saving Boiler Feed Water Treatment Solution with PLC Control is a fully automatic boiler feed water treatment system designed for industrial steam boiler applications. This advanced industrial boiler water treatment equipment integrates pretreatment filtration, water softening, reverse osmosis, and intelligent PLC automation to provide stable, high-purity boiler make-up water.

This RO system for boiler feed water removes hardness, suspended solids, dissolved salts, silica, conductivity, and corrosion-causing contaminants before water enters the steam boiler system. By improving feed water quality, the system helps reduce scaling, corrosion, boiler tube blockage, unstable steam pressure, and excessive fuel consumption.

As a professional steam boiler feed water system, it improves thermal efficiency, lowers maintenance costs, minimizes downtime, and extends boiler service life.

2. Why High-Quality Boiler Feed Water Is Important

Industrial boilers require clean and stable feed water to maintain safe and efficient operation. Poor-quality water may contain hardness ions, silica, chloride, suspended solids, dissolved oxygen, and high conductivity salts, which can seriously damage the boiler system.

Water Problem Possible Boiler Damage
Hardness Ca²⁺ / Mg²⁺ Scale formation inside boiler tubes
Dissolved Oxygen Corrosion and rust
High Conductivity Steam carryover
Silica Turbine and steam contamination
Suspended Solids Pipeline blockage
Chloride Metal corrosion
Organic Matter Membrane fouling and instability

A high-efficiency boiler water filtration system and reverse osmosis system for boiler can reduce these risks while improving steam quality and operational stability.

3. Application Areas

This automatic boiler feed water solution is widely used in:

  • Industrial steam boiler systems
  • Textile factory boilers
  • Food and beverage steam systems
  • Chemical plant boilers
  • Pharmaceutical utility boilers
  • Hotel and hospital boiler rooms
  • Power plant auxiliary boilers
  • Electronics industry boiler systems
  • Central heating boiler stations
  • Laundry steam boilers
  • Rubber and plastic factory boilers
  • Industrial thermal oil heating systems

4. Standard Process Flow Diagram

Boiler Feed Water Treatment Process

Raw Water Tank → Raw Water Pump → Multi-Media Sand Filter → Activated Carbon Filter → Water Softener → Precision Filter → High Pressure Pump → Reverse Osmosis System → RO Water Tank → UV Sterilizer Optional → Degassing / Deaeration Unit Optional → Boiler Feed Water Tank → Boiler Feed Pump → Steam Boiler System

5. Technical Parameters

Model Capacity RO Recovery Rate Product Water Conductivity Power Supply PLC Control
CY-BFW-1000 1 T/H 50–65% ≤10 μS/cm 380V / 50Hz Yes
CY-BFW-3000 3 T/H 50–70% ≤10 μS/cm 380V / 50Hz Yes
CY-BFW-5000 5 T/H 50–70% ≤8 μS/cm 380V / 50Hz Yes
CY-BFW-10000 10 T/H 60–75% ≤5 μS/cm 380V / 50Hz Yes
CY-BFW-15000 15 T/H 60–75% ≤5 μS/cm 380V / 50Hz Yes
CY-BFW-20000 20 T/H 60–75% ≤5 μS/cm 380V / 50Hz Yes

This high efficiency boiler feed water system can be customized according to raw water quality and boiler capacity requirements.

6. Main Configuration List

Component Function
Raw Water Tank Raw water storage
Multi-Media Filter Removes suspended solids
Activated Carbon Filter Removes chlorine and organics
Water Softener Removes hardness ions
Precision Filter Protects RO membranes
High Pressure Pump Provides RO operating pressure
RO Membrane System Removes dissolved salts
UV Sterilizer Controls microorganisms
PLC + HMI Control System Automatic operation and monitoring
Conductivity Meter Online water quality monitoring
Flow Meter System flow monitoring
Electrical Cabinet Centralized electrical control

7. Energy Saving Advantages

  • Reduced boiler scaling
  • Improved heat transfer efficiency
  • Lower fuel consumption
  • Reduced chemical dosing cost
  • Lower maintenance frequency
  • Longer boiler lifespan
  • Stable steam production
  • Reduced boiler shutdown risk
  • Lower operational cost
  • Intelligent automatic operation

8. Certification Standards

  • ISO 9001
  • CE Certification
  • SGS Inspection
  • IEC Electrical Standards
  • Pressure Vessel Safety Standards
  • GMP Utility Design Concept
  • ASME BPE Design Reference Optional

9. FAQ

Q1: Why is RO technology important for boiler feed water?

RO technology removes dissolved salts, hardness, silica, and conductivity, helping reduce boiler scaling and corrosion risks.

Q2: Can the system reduce boiler fuel consumption?

Yes. Cleaner boiler tubes improve heat transfer efficiency, helping reduce fuel consumption and operating costs.

Q3: Is PLC automatic control available?

Yes. The system supports automatic operation with alarms, conductivity monitoring, and automatic flushing functions.

Q4: Can the system be customized for different boiler capacities?

Yes. The system can be customized according to boiler pressure, steam demand, raw water quality, and installation layout.

Q5: What membrane brands are available?

Optional membrane brands include Vontron, DOW, Hydranautics, and Toray.

10. CAT

  • Intelligent PLC automatic control
  • Stable boiler feed water quality
  • High salt rejection efficiency
  • Reduced boiler scaling risk
  • Energy-saving operation
  • Reduced fuel consumption
  • Compact skid-mounted structure
  • Easy maintenance
  • Long membrane lifespan
  • Customized engineering design
  • OEM manufacturing support
  • Turnkey project capability

11. Contact Us

Looking for a reliable Energy Saving Boiler Feed Water Treatment Solution with PLC Control?

Contact our engineering team today for customized process design, boiler water analysis, technical consultation, layout drawings, competitive quotation, and turnkey project support.

Contact Details
Shanghai ChongYang Water Treatment Equipment CO.,LTD.

Contact Person: Ms. Yanni.Wang

Tel: 86 15900488030

Fax: 86-21-66126659

Send your inquiry directly to us