Product Details:
Payment & Shipping Terms:
|
| Feed Water Salinity: | ≤45000 Ppm | Water Source: | Seawater |
|---|---|---|---|
| Technology: | Reverse Osmosis RO | Product Water Capacity: | 5–1,000 M³/day Or Customized |
| Product Water TDS: | <500 Ppm,subject To Feed Conditions | RO Membrane Brand: | DOW / Toray / Hydranautics |
| Pretreatment System: | Sand Filter + Carbon Filter | Desalination Rate: | ≥99.5% |
| Membrane Housing: | FRP / SS316L | Recovery Rate: | 35% – 45% |
| Voltage: | 220V / 380V / 415V | Application: | Hotels / Resorts / Islands / Coastal Properties |
A Seawater Desalination Plant for Hotels and Resorts provides an independent freshwater supply for island resorts, beachfront hotels, coastal properties, villas, and remote hospitality facilities where municipal freshwater is limited, expensive, or unavailable.
Using Seawater Reverse Osmosis (SWRO) technology, the system removes dissolved salts and other contaminants from seawater and produces freshwater for guest rooms, kitchens, laundry, staff facilities, swimming-pool makeup, landscaping, and other hotel utility requirements.
CHONGYANG Water supplies compact skid-mounted, modular, and containerized SWRO plants with capacities from small hotel systems to large multi-train desalination plants for island resorts.
A hotel SWRO plant is a complete water-treatment system designed to convert seawater into usable freshwater through high-pressure reverse osmosis.
Unlike a standard industrial RO system, seawater desalination must operate against the high osmotic pressure of seawater. Therefore, the plant requires dedicated SWRO membranes, high-pressure pumping, corrosion-resistant materials, appropriate pretreatment, chemical dosing, and automatic process control.
For potable-water applications, RO permeate can be further treated by remineralization, pH adjustment, UV, or chlorination according to the required final water specification.
A typical hotel and resort seawater desalination process is:
Mobile: Swipe horizontally to view the complete SWRO process.
The required desalination capacity should be calculated according to total daily consumption, peak demand, occupancy rate, laundry requirements, kitchen consumption, irrigation demand, and product-water storage capacity.
| Product Capacity | Typical Application | Recommended Configuration |
|---|---|---|
| 5–10 m³/day | Villas / Boutique Hotels | Compact SWRO Skid |
| 10–30 m³/day | Small Hotels / Guesthouses | Pretreatment + SWRO |
| 30–50 m³/day | Small Coastal Resorts | Automatic SWRO Plant |
| 50–100 m³/day | Medium Hotels & Resorts | Full Pretreatment + SWRO |
| 100–300 m³/day | Large Island Resorts | SWRO + ERD + Post-Treatment |
| 300–1,000 m³/day | Large Hotel Complexes | Multi-Train SWRO Plant |
On mobile devices, swipe horizontally to view the complete capacity table.
| Parameter | Typical Design |
|---|---|
| Feed Water | Seawater |
| Feed TDS | Up to 45,000+ mg/L, subject to design |
| Technology | Seawater Reverse Osmosis (SWRO) |
| Capacity | 5–1,000 m³/day or Customized |
| Operating Pressure | Approx. 55–70 bar |
| Recovery Rate | Approx. 35–50% |
| Salt Rejection | Typically ≥99.5% |
| Installation | Skid-Mounted / Containerized |
| Control | PLC + HMI Automatic Control |
| Post-Treatment | Remineralization / UV / Chlorination |
For boutique hotels, beach villas, and small resorts, the SWRO system can be integrated on a compact skid to minimize installation space.
For remote islands and outdoor installations, the complete seawater desalination system can be integrated into a 20-foot or 40-foot container.
The containerized plant can integrate pretreatment, chemical dosing, cartridge filtration, high-pressure SWRO, energy recovery, CIP, instrumentation, and PLC control into one modular package.
Factory pre-assembly reduces site installation work and provides additional protection against rain, salt spray, dust, and harsh coastal environments.
A seawater desalination plant should not be designed according to capacity alone. Raw-water chemistry directly affects pretreatment, membrane selection, operating pressure, recovery, chemical dosage, and final water quality.
Capacity depends on guest numbers, occupancy, laundry, kitchens, staff facilities, swimming pools, landscaping, daily operating hours, and product-water storage.
Yes. Appropriate remineralization, pH adjustment, and disinfection should be applied according to the required drinking-water standard and local regulations.
Hotel and resort SWRO plants commonly operate at approximately 35–50% recovery, depending on seawater chemistry, temperature, membrane design, and operating conditions.
Yes. Pretreatment, SWRO, dosing, CIP, instrumentation, and automatic control can be integrated into a containerized package according to plant capacity.
An ERD is particularly beneficial for medium and large SWRO plants with long operating hours because it can reduce the energy demand of the high-pressure desalination process.
A reliable hotel seawater desalination plant requires more than an RO membrane. Pretreatment, high-pressure equipment, SWRO membrane configuration, energy recovery, post-treatment, automation, and freshwater storage must be engineered as one complete system.
CHONGYANG Water provides customized seawater desalination plants from compact skid-mounted systems for boutique hotels to containerized and multi-train SWRO plants for large island resorts.
Send us your raw seawater analysis, required capacity, daily operating hours, hotel room quantity, final water application, power supply, and project location.
Our engineering team can select the appropriate pretreatment, SWRO membrane configuration, recovery rate, energy-recovery solution, and post-treatment process for your project.